Features
- Calculates CP
on line (no tables , no extrapolation ) .
- Fully Programmable
(all stages of heat treatment ) .
- Backlit LCD display
(large size ) .
- Latest Technology
- RS 232 interface
- Highly Reliable
|
Input
/ Output Specifications
|
| Keyboard
|
|
Membrane Keypad , 9 keys |
| Oxygen
Probe |
|
Zirconia
Sensor based |
| Dimensions
( W*H*D) |
|
340
* 130 * 240 mm |
| Thermocouple |
|
K
,R or N Type |
| Display |
|
Backlit
LCD Display , large size , 2 line
Default : Instantaneous process values and
temperature.
Prompted :Millivolt ,set point values, current
cycle and alarms.
LED indication for current cycle and alarms. |
| Relay |
|
4
Potential free contacts (sink current -200 mA max ) |
| RS
232 |
|
9600
baud , no parity , one stop bit |
| Alarms |
|
T/C
fail , Sensor fail , End of cycle and Change of cycle . |
|

|
General
Specifications
|
| Power
Supply |
|
230 V AC / 50 Hz ,± 10% |
| Ambient
Temperature |
|
Upto
55° C |
| Dimensions
( W*H*D) |
|
340
* 130 * 240 mm |
| Weight |
|
4
kg |
| Principle |
|
The
controller calculates CP from input data from the Probe as well as
the programmable CO percentage in the furnace and controls the carburisation
process at the set values of CP . |
|
Control
Cycles
|
| Heating |
|
Process fluid (e.g. methanol ) started at operator set temperature
.Boost fluid (e.g. acetone ) switched on at a higher preset
temperature. |
| Carburisation
/ Boost |
|
The
system controls CP at the set value (high CP) by controlling the
boost fluid flow. |
| Diffusion |
|
At
the end of the carburisation cycle , the system automatically switches
the set point to the low CP value specified for diffusion ad controls
the process till the diffusion cycle is over. |
| Weight |
|
4
kg |
| Cooling |
|
The
process fluids are switched off at the preset temperature. |
|